Summary

About 1,000 W continuously, on most 100 Ah lithium batteries. At 12.8 V and 90% inverter efficiency, a 1,000 W load pulls about 87 A from the battery, a 2,000 W load about 174 A and a 3,000 W load about 260 A. Victron's Lithium NG 100 Ah allows 100 A continuous; its Lithium Smart 100 Ah allows 200 A but recommends 100 A or less. Renogy's 12 V inverters are sold at 700, 1,000, 2,000 and 3,000 W, with surge ratings of double and no-load draws of 0.8 to 2.5 A, and the datasheet shuts the inverter down at 10.5 V.

Current at full load

Inverter ratingBattery current at 12.8 V, 90% efficiencyRenogy surge ratingRenogy no-load draw
700 Wabout 61 A1,400 W0.8 A
1,000 Wabout 87 A2,000 W1.0 A
2,000 Wabout 174 A4,000 W2.0 A
3,000 Wabout 260 A6,000 W2.5 A

The current column is our arithmetic. Renogy's datasheet gives the surge and no-load figures and does not state efficiency per model; its 2,000 W product page says "over 90%," which is the figure we used.

Against the battery's data sheet

BatteryMax continuous dischargeLargest inverter at full load
Victron Lithium NG 12.8 V/100 Ah100 A (1C)1,000 W (about 87 A)
Victron Lithium Smart 12.8 V/100 Ah200 A, 100 A recommended2,000 W at the maximum; 1,000 W within the recommendation
Victron Lithium NG 12.8 V/300 Ah300 A (1C)3,000 W (about 260 A)
Victron Lithium Smart 12.8 V/330 Ah400 A, 300 A recommended3,000 W

Surge is the second check. A 2,000 W inverter's 4,000 W surge would ask about 350 A for a moment; the NG 100 Ah lists a 200 A ten-second peak, so even the brief start of a large motor is outside it. Two batteries in parallel double both limits, which is the usual answer when the inverter is bigger than the battery.

The voltage cut-off is the other way to lose power

Renogy's inverters sound a low-battery alarm at 11 V ±0.3 and shut down at 10.5 V ±0.3. A lithium battery holds voltage until it is nearly empty, so the shutdown arrives late and suddenly; heavy loads also pull the terminal voltage down, which can trip the alarm with charge still in the cells.

Idle draw is paid every hour

The no-load currents above become 0.8 to 2.5 A around the clock if the inverter stays on: about 290 Wh a day for the 1,000 W unit and about 580 Wh for the 2,000 W, a quarter to nearly half of a 100 Ah battery's 1,280 Wh. Switch the inverter off, or use the remote switch Renogy includes, when nothing needs AC. The 3,000 W unit ships without battery cables.

Shopping for one? Browse RV and off-grid solar panels →

Sources

  1. Victron Energy — Lithium NG 12,8 V manual, Technical data
  2. Victron Energy — Lithium Smart Battery Manual, 7. Technical data
  3. Renogy — 12V Pure Sine Wave Inverter datasheet (700/1000/2000/3000 W)
  4. Renogy — 2000W 12V Pure Sine Wave Inverter

We have not tested these products. Specs, prices, stock and terms are as published on these pages on the date above and can change; check the manufacturer or retailer before you buy.

More RV, off-grid and 12V systems guides

RV, off-grid and 12V systemsWhat Makes Up an RV Electrical System, and Where Does Solar Fit In?An RV runs mainly on DC power stored in a leisure (house) battery. Solar is one way to refill that battery; shore power, the engine's alternator, and…Read the guide →RV, off-grid and 12V systemsHow Many Watts of Solar Does an RV Need for 720 Wh a Day?If the goal is only to replace each day's use, Victron Energy's worked example lands at 144 W. Victron itself calls that not ideal for an RV that…Read the guide →RV, off-grid and 12V systemsHow Many Watts of Solar Does a Shed Actually Need?It depends on what runs inside, not on the shed's floor area. A 20 W LED light for 3 hours, a 5 W camera around the clock, and 60 Wh of tool-battery…Read the guide →RV, off-grid and 12V systemsBefore Adding Solar to a Mobile or Manufactured Home, Where Do You Look First?At the data plate, a paper label fixed inside the home. HUD rules require it to state the roof load zone and wind load zone the home was designed for…Read the guide →RV, off-grid and 12V systemsIn What Order Do You Size the Battery and Panels for an Off-Grid Solar System?Start with daily watt-hours. The battery is sized by how many sunless days it has to cover, and the array by whether it can put that energy back each…Read the guide →RV, off-grid and 12V systemsDoes the Wattage in an Off-Grid Solar Kit's Name Tell You What You Are Buying?No, as two 12 V kits from Renogy show. The 200W Essential Kit's package list has two panels, a PWM charge controller, and cabling, with no battery or…Read the guide →RV, off-grid and 12V systemsWhat Does a Solar Charge Controller Do, and What Do the Numbers in "100/30" Mean?It sits between the panels and the battery and turns the array's output into charging the battery can take. Victron's MPPT controllers lock onto the…Read the guide →RV, off-grid and 12V systemsHow Much More Power Does an MPPT Controller Harvest Than PWM, and When Does the Gap Close?In Victron's worked example, a 100 W, 36-cell panel charging a 12 V battery at 25°C cell temperature yields 81 W through a PWM controller, 19% less…Read the guide →RV, off-grid and 12V systemsFor a 12V Solar Charge Controller, How Far Can Panel Voltage and Wattage Go?"12V" describes the battery side. The panel side has its own limits: on a Victron SmartSolar MPPT 100/30, open-circuit voltage from the array must…Read the guide →RV, off-grid and 12V systemsWhy Does a 12V Solar Setup Need Much Thicker Wire Than a 48V One?Current and cable length set the wire size, and system voltage sets the current. Moving 2,400 W takes 200 A at 12 V but only 50 A at 48 V, so the same…Read the guide →RV, off-grid and 12V systemsWhy Does One Solar Panel Kit Cost $290 and Another $3,200?Mostly because of the battery and the inverter. In Renogy's Solar Kits collection, a 200 W kit with two panels and a charge controller sells for…Read the guide →RV, off-grid and 12V systemsDoes an Inverter on a 12V Solar Kit Drain the Battery Even With Nothing Plugged In?Yes. Victron's Phoenix Inverter 12/375 draws 5.6 W at zero load, about 134 Wh over 24 hours. Renogy's 2,000 W inverter lists a no-load current under…Read the guide →RV, off-grid and 12V systemsWhat Changes When an RV's Victron MultiPlus-II Goes From Shore Power to Battery?On shore power or a generator, the U.S. MultiPlus-II 2x120V passes that AC straight through to the RV's loads and charges the battery at the same…Read the guide →RV, off-grid and 12V systemsCan One 300 W Panel Refill a 12 V, 100 Ah Battery in a Day?The annual-average model is above the battery's nominal energy in Phoenix and below it in New York and Seattle, before battery-charging losses. It…Read the guide →RV, off-grid and 12V systemsWhat Do the Numbers Next to "100Ah" on a LiFePO4 Battery Spec Sheet Tell You?How capacity shrinks in the cold, the temperatures at which the battery can be charged, the maximum and recommended currents, and the conditions…Read the guide →RV, off-grid and 12V systemsHow Much Do Gel and LiFePO4 Batteries of the Same Size Differ in Weight and Cycle Life?Among Victron's own products, by more than three times in weight and five to seven times in cycle count. The 12 V GEL Deep Cycle 110 Ah weighs 33 kg…Read the guide →RV, off-grid and 12V systemsHow Many Watts of Panel Does It Take to Refill a 12 V 100 Ah Battery Each Day in December Versus July?In New York, about 630 W in December and about 280 W in July. A 12.8 V, 100 Ah battery holds 1,280 Wh, and the panel wattage needed to put that back…Read the guide →RV, off-grid and 12V systemsHow Many Amps Can an RV Lithium Battery Take From the Alternator, Shore Power, and Solar?Using Victron products, up to 50 A from the alternator through an Orion XS 12/12-50A, 30 A from shore power through a Blue Smart IP22 12/30, and up to…Read the guide →RV, off-grid and 12V systemsHow Many Solar Watts Keep a Starlink Mini Online Around the Clock?At the top of the Mini's listed average draw, 40 W, a full day comes to 960 Wh. Run through NLR's PVWatts model for New York, that takes roughly 270 W…Read the guide →RV, off-grid and 12V systemsWhich Ring Cameras Does Each Ring Solar Panel Plug Into?Ring's compatibility list assigns its barrel-plug Solar Panel (2.4W) to one group of cameras and its USB-C Solar Panel and Small Solar Panel to…Read the guide →RV, off-grid and 12V systemsWhy Is Rich Solar's 1600W Kit Built at 24V Instead of 12V?Because its charge controller takes only 800 W of solar at 12 V. The RS-MPPT60 in the 1600 Watt 24V Complete Solar Kit is rated for a maximum solar…Read the guide →RV, off-grid and 12V systemsHow Is BougeRV's Yuma CIGS Panel Different From the 100W Arch Pro?The Yuma 100W is a CIGS thin-film panel with 17% cell efficiency, against 25% for the Arch Pro 100W, so it needs about a fifth more area for the same…Read the guide →RV, off-grid and 12V systemsCan a Harbor Freight Thunderbolt 100W Panel Go Straight to a Battery?The owner's manual says no. The manual for SKU 71049 tells buyers to use an appropriate charge controller, sold separately, whenever the panel is…Read the guide →RV, off-grid and 12V systemsHow Many Miles a Day Can Solar Panels on a Car Add?Toyota says the 185 W solar roof on its latest Prius plug-in hybrid adds up to 8.7 km, about 5.4 miles, of electric range a day, based on annual…Read the guide →RV, off-grid and 12V systemsVictron Lithium Smart or Lithium NG at 12.8 V: What the Technical Data Pages Say ChangedSame energy per amp-hour, different current limits, weight and electronics. The older Lithium Smart 12.8 V/100 Ah lists a 200 A maximum continuous…Read the guide →RV, off-grid and 12V systemsWhat $799.99 Buys in Rich Solar's Basic 400 Watt Kit, What It Leaves Out, and Why 400 W Sits Right at a 30 A Controller's LimitTwo 200 W panels, a 30 A MPPT controller, brackets, fuse holder and cables, and nothing that stores or inverts power. At 12 V, 400 W of panel is about…Read the guide →RV, off-grid and 12V systemsWhy a Lithium RV Battery Will Not Charge Below 5 °C, and What That Means for Winter TripsVictron's technical data for both its Lithium Smart and Lithium NG 12.8 V batteries gives two temperature windows: discharge from −20 °C to +50 °C…Read the guide →RV, off-grid and 12V systemsOrion XS 50 A, 70 A or 1400: Picking a Victron DC-DC Charger From the Battery's Charge LimitStart with what the battery accepts, not with what the alternator can give. Victron's Lithium NG 100 Ah charges at 100 A maximum, so either the Orion…Read the guide →